10KW off-grid Inverter Battery for Home Solar Power System
48V100AH 5U BATTERY PACK for HOME ENERGY STORAGE SYSTEM
Share to:
  • Product details

    item

    Parameters & Options

    Input voltage waveform

    Sine wave (ACorGenerator)

    Rated input voltage

    230Vac

    Low voltage breakpoint

    184Vac±4%

    Low pressure recovery point

    194Vac ±4%

    Hv breakpoint

    253Vac±4%

    High voltage recovery point

    243Vac±4%

    Maximum input voltage

    270Vac rms

    Rated input frequency

    50Hz/ 60Hz  (automatic detection)

    Low voltage recovery point frequency

    58+0.3Hz(60Hz);48+0.3Hz(50Hz);

    Low voltage breakpoint frequency

    57+0.3Hz(60Hz);47+0.3Hz(50Hz);

    High voltage recovery point frequency

    64+0.3Hz(60Hz);54+0.3Hz(50Hz);

    High - voltage breakpoint frequency

    65+0.3Hz(60Hz);55+0.3Hz(50Hz);

    Output voltage waveform

    Consistent with the input voltage waveform

    Overload protection

    Circuit breaker starts

    Short circuit protection

    Circuit breaker starts

    Power efficiency

    >95%

    Convert current

    30Aac

    AC to DC conversion time

    10ms

    DC to AC conversion time

    10ms

    Bypass switching current

    Yes

    Bypass maximum load current

    30Aac

    Output voltage waveform

    Pure sine wave

    Rated output capacity (VA)

    5000

    Rated output power (W)

    5000

    Power factor

    0.9-1.0

    Rated output voltage (V)

    230Vac

    Rated output frequency (Hz)

    50Hz ± 0.3Hz

    Automatic tracking frequency (Hz)

    50Hz @48-54Hz 60Hz @58-64Hz

    Output voltage range

    ±10% rms

    effectiveness

    >85%

    Overload protection

    (110%

    (125%

    Load> 150% ± 10%: Disconnect the output voltage after 20 seconds

    Peak capacity (10s)

    12000VA

    Motor starting ability

    2 HP

    Short circuit protection

    Current limit (power off after 10s)

    Circuit breaker specifications

    30A

    Rated DC input voltage

    48Vdc

    Minimum DC voltage

    40Vdc

    Undervoltage warning

    42Vdc ± 0.3Vdc

    DC input voltage is too low

    40Vdc ± 0.3Vdc

    Input over-voltage warning and power failure

    64Vdc ± 0.3Vdc

    Input overvoltage recovery

    62Vdc± 0.3Vdc

    Power-saving mode to enter the conditions

    Load ≦ 25W Enter power saving mode, load> 25W to enter normal mode

    Nantong Ningyuan Automation
    Tel :
    E-mail:
    Fax: :
    Add::
    Wechat official account
    0513-83598587
    info@cnntny .com
    +86-513- 8106
    11#c, 299 Kerun road, Gangzha District, Nantong, China
    Copyright:Nantong Ningyuan Automation Technology Co., LtdCopyright:Nantong Ningyuan Automation Technology Co., Ltd
    batteries / battery / solar panel / battery cell/ lithium battery/ battery pack /
    lithium ion battery / 18650 battery / Lifepo4 battery / UPS / storage battery /
    rechargeable battery / 38120HP / lipo battery / square battery / solar cell / li-ion battery /​