EN
48v360AH
1.Application  Thespecificationdescribesthetype,performance,testconditions,precautions,shelflife,transportationmethods,andtechnicalconsultingconditionsofthemodel43184/24V360Ah-8S18Plithiumironphosphat
Share to:
  • Product details

    1. Application

      The specification describes the type, performance, test conditions, precautions, shelf life, transportation methods, and technical consulting conditions of the model 43184 / 24V360Ah- 8S18P lithium iron phosphate battery packs for power. The specification is applicable to the 43184 / 24V360Ah lithium-ion battery pack developed and produced by Nantong Ningyuan Automation Technology Co,Ltd. based on 43184 / 20Ah lithium ion cells.

      2. Type & Model

      Type:Lithium Iron Phosphate Battery Pack

      Model:43184 -24V360AH

      3. Single Cell Parameter

     

    Item

    Specification

    Nominal Capacity

    20Ah

    Nominal Voltage

    3.2V

    Resistance

    ≤ 4mΩ

    Standard Charge Current

    1C

    Max Charge Voltage

    3.65V

    Standard Discharge Current

    1C

    Continuous Discharge Current

    3C

    End-Off Discharge Voltage

    2.5V

    Working Temp.

    -20~60℃

    Cell Diameter

    43±0.5mm

    Cell Height

    184

    Weight

    ≤530±5g

    Charge Temp Range

    0℃~45℃

    Discharge Temp Range

    -20℃~55℃

    Storage Temp Range

    -10℃~45℃

     

     

      4. Battery pack performance

     

    Model

    43184/ 24V360Ah

    Connector Method

    144 pcs43184 cells in series and Parallel

    Nominal Capacity(AH)

    360Ah

    Rated Volt(V)

    24 V

    Over-Voltage Alarm value

    29.2V

    Over-Voltage Alarm Recovery value

    27.2V

    Over-Voltage protection value

    29.6V

    Under-voltage alarm value

    22.4V

    Under-voltage Alarm Recovery value

    24.4V

    Under-voltage protection value

    20.8V

    Under-voltage protection recovery value

    22.8V

    Rated Power(Wh)

    8.64kWH

    Operation Temp Range

    0℃~50℃

    Max Charge Volt

    29.2V

    End-off Discharge Volt

    20.8V

    Max Charge Current

    360A

    Max Continuous Output Current

    720A

    Protection Type(PCB)

    Over-Charge, over-discharge, over-current, short circle

    Operation Humidity

    <90%

    House Material

    Metal

     

      5.Test Conditions

      Experiments and measurements are performed at standard temperature (20±5°C) and standard humidity (65±20%).

      Standard charging: Charging with a matching charger, charging is stopped when the indicator light changes from red to green.

      Standard discharge: Constant current at 0.2C discharged to 20.8V.

      6. Performance

      6.1 Exterior

      The outer surface of the battery is clean, no electrolyte leakage, no obvious scratches and mechanical damage, no deformation, no corrosion of the contacts, There are no other appearance defects that affect the battery's value, and the surface has the necessary product identification.

      6.2 Performance

     

    Item

    Testing process

    Standard

    Open circle Volt

    Test the open circle voltage in 1 hour after standard charge

    29.2V

    Nominal Capacity

    Discharge to 20.8V by CC at 0.2C in 5 hours after

    standard charge

    Capacity≥360Ah

    Charge-Discharge Cycle Life

    The cycle life is end when the 2 consecutive times

     discharge time less than 1.6hours according to

     standard charge-discharge cycle at 25±5℃

    ≥2000cycles

    Soc

    Stay 28 days at 25±5℃ after standard charge, then

     discharge to end-off voltage at 0.2C, the discharge

    capacity ≥90% nominal capacity

    Capacity≥324Ah

    High Temp

    performance

    Stay 4 hours at 60±2℃ after standard charge, then

     discharge to end-off voltage at 0.2C, the discharge

    capacity ≥90% nominal capacity

    Capacity≥324Ah

    Low Temp

    performance

    Stay 4 hours at -20±2℃ after standard charge, then

    discharge to end-off voltage at 0.2C, the discharge

    capacity ≥90% nominal capacity

    Capacity≥216Ah

    Extruding

    (Single Cell)

    Put the battery between the two extrusion planes of the

     extrusion equipment, gradually increase the pressure

     to 13kN, keep the pressure for 1min. Its longitudinal

    axis should be parallel to the extrusion surface and

    perpendicular to the extrusion direction. Only one

    squeeze test per battery

    No fire,

    no explosion

    Thermal shock

    (Single Cell)

    Put the battery in the heating box, temperature is

    increased to 130 °C ± 2 °C at a rate of (5 ± 2) °C/min

     and kept warm for 30 minutes,

    then remove and return to room temperature

    No fire, no

    explosion

    Over-Charge

    (Single Cell)

    The test should be conducted in an environment of 20±5°C.

    The battery discharges to the end-off voltage at 0.2C current

     first. Put the battery in a fume hood. Connect the positive and

     negative of the battery to the DC power supply. Adjust the output

     current of the power supply to 3C. The output voltage is not

     lower than 10V. Continuous charging for 7 hours or the

    voltage is not increase any more, current decrease to zero.

    No fire, no

    explosion

    Forced discharge

    (single Cell )

    The test shall be conducted in an environment of 20±5°C. The battery shall be discharged to the end-off voltage at 0.2C current first, and then reverse charge to the battery with 1C current

     90min.

    No fire, no

     explosion

    Short Circle

    (single Cell)

    After full charge according to the standard, put the

    battery with thermocouple in the fume hood (total line

     resistance is less than 50mΩ), short circuit the

    positive and negative poles, monitor the battery

     temperature during the test, end of the test when the battery temperature is lower than its peak value 10°C.

    No fire, no

    explosion, the surface temp less than

    150℃

    Acupuncture

    (single cell)

    The test should be conducted in an environment of 20±5°C.

    Charge the battery to the limit voltage according to the

    standard. A thermocouple is connected to the maximum surface area of the battery and place in a fume hood. A

    stainless steel needle with 3mm diameter is used to

     pierce the center of the largest surface of the battery at

    a rate of 20 mm to 40 mm/s and hold for 1 min.

    No fire, no

    explosion

    Heavy Impact

    (Single Cell)

    The battery is placed on a flat surface and a Φ15.8

    mm steel column is placed in the center of the

    cell. The longitudinal axis of the steel column is

    parallel to the plane, allowing 9.1 kg of weight to fall

     freely from a height of 610 mm to the steel column

     above the cell center.

    No fire,

     no explosion

     

      7. Transport

      Batteries should be packed into boxes for transportation under the SOC of 20 ~ 50%. During transportation, severe vibration, impact or squeezing should be prevented to prevent sun and rain. It should be applicable to cars, trains, ships, aircrafts, etc. Ordinary means of transport.

      8. Storage

      The battery should be stored in a clean, dry and ventilated environment with a temperature of 20±5°C and a humidity of 65±20% RH. Contact with the erodible substance should be avoided. Keep away from fire and heat sources. Charging every 3 months during battery storage. In the process of battery processing, when using the stock cell and the battery delivery, all should follow the principle of "first in, first out"

      9. Packing and signage

      9.1 Packing

      The outside of the packing box should indicate the product name, model number, quantity, gross weight, manufacturer and contact address, and the date of manufacture. There should also be necessary signs such as “Handle with Care”, “Fear of Wetness”, and “Upwards”. The signs of its packaging, storage and transportation shall comply with the provisions of GB-191-2000

      9.2 signage

      Each battery shall have the following Chinese information: product name, model number, nominal voltage, nominal capacity, positive and negative polarity trademarks and warning instructions, and manufacturing date, lot number, manufacturer name, (or serial number including the above data )

      10. Remark

      With the above, it can be used as a framework for the agreement between the supply and demand sides on the performance and inspection rules of battery products. If there is no new written agreement or change notice, will operate according this. If you find any problem with this specification, it must be approved by both parties before modifying

      11. Appendix

      11.1 Instructions for use and safety procedures

      11.1.1 Recommended use

      read the instruction manual and the surface of the battery carefully, before using the battery,

      Please use the battery in normal indoor environment, temperature: 20±5°C, relative humidity: 65±20%

      Keep away from heat and high pressure, avoid children playing with batteries, and do not beat the battery during use.

      The battery can only be charged using the accessory charger. Do not put the battery in the charger for more than 24 hours.

      Do not short-circuit the positive and negative terminals of the battery. Do not disassemble the battery yourself. Do not place the battery in a damp place to avoid danger.

      When the battery is not used for a long period of time, please keep the battery in good condition and leave the battery in a half of SOC. Recharge it every 6 months. Do not wrap the battery with conductive material to avoid direct metal contact with the battery and damage the battery. Store the battery in a cool, dry place.

      Dispose of the battery safely and properly. Do not put it into fire or water.

      Danger warning

      Do not disassemble and assemble battery: Inside the battery has a protection mechanism and protection circuit to avoid danger. Inappropriate disassembly will damage the protective function and cause the battery to heat, smoke, deform or burn

      Do not short-circuit the battery: Do not connect the positive and negative terminals of the battery with metal. Do not store and move the battery together with the metal sheet. If the battery is short-circuited, excessive current will flow through it, which will damage the battery and cause the battery to heat, smoke, deform or burn.

      It is forbidden to heat and incinerate the battery: heating and incineration of the battery will cause the battery separator to melt, lose safety function or electrolyte burning, and the overheat will cause the battery to generate heat, smoke, deformation or burning.

      Avoid using the battery near the heat source: Do not use the battery in the vicinity of the fire source, the oven, or in excess of 80°C. Overheating will cause short circuit in the battery, causing the battery to generate heat, smoke, and deformation or burning.

      Do not get wet the battery: Do not get wet or put the battery into water. Otherwise it will cause the internal protection circuit and function of the battery to be lost and abnormal chemical reaction. The battery may have heat, smoke, deformation or burning.

      Attention

      Note: avoid using batteries in strong sunlight and exposure to avoid heat, smoke and deformation, at least avoid battery performance degradation and life expectancy reduction.

      Anti static: battery is equipped with protection circuit to avoid all kinds of accidents. Do not use the battery in the place where the static electricity is produced, because the static electricity is easy to damage the PCB, which causes the battery work to be abnormal, heat, smoke, deform or fire.

      Charging mode: please use special charger and recommended charging mode to recharge the battery under the recommended environmental conditions.

      Safe use protection: Please discuss with suppliers about the perfection of protection function, if battery is used for other equipment,.

      The battery should be charged immediately, When the battery pack is under voltage protection.

      Quality assessment

      Quality inspection is divided into appraisal inspection and quality consistency inspection. Appraisal inspections are generally conducted during the Design setting, change design and production setting. Sampling plans, inspection items, orders, and rules for determination are determined by both the supplier and the buyer. In principle, the above performance tests should be included. The quality consistency inspections are divided into batch inspections and periodic inspections to determine whether or not the products can be qualified in the production process to ensure the continued stability of product quality. Please refer to GB2828-1987 standard implementation. Inspection items shall include appearance, internal resistance, rated capacity or 1C5A discharge capacity, etc.

      11.3 Environmental requirements

      This product meets ROHS environmental protection requirements

      Warning: This design plan changes with product requirements without notice



    Nantong Ningyuan Automation
    Tel :
    E-mail:
    Fax: :
    Add::
    Wechat official account
    0513-83598587
    info@cnntny .com
    +86-513- 8106
    11#c, 299 Kerun road, Gangzha District, Nantong, China
    Copyright:Nantong Ningyuan Automation Technology Co., LtdCopyright:Nantong Ningyuan Automation Technology Co., Ltd
    batteries / battery / solar panel / battery cell/ lithium battery/ battery pack /
    lithium ion battery / 18650 battery / Lifepo4 battery / UPS / storage battery /
    rechargeable battery / 38120HP / lipo battery / square battery / solar cell / li-ion battery /​